Homework 1
The position of a slider-crank mechanism is required to be mm when
. If the actual position
is outside the tolerance
range
mm, it is considered that a failure occurs.
The design variables are independent and follow normal distributions of
,
, and
. Use the First Order Second Moment
(FOSM) method to calculate the probability of failure.
(Ans. )